KMS - Demonstration of False Signal Processing
The false signal processing is automatic
by default and in most instances you will only make small adjustments in the
settings for a jump test versus a sprint timing test. for this
demonstration it isinstructive to alter the settings of the processor and then observe the
resulting changes in the timings because manual fine tuning can improve the
results.
|
Step 1.
|
|
Run the KMS program by clicking the Start
button on the Windows toolbar. If you do not have the
software installed on your computer you can download a fully functional version
by clicking here
|
image to small? LARGER IMAGE
|
|
Step 2.
|
|
Select view and then click 'On-Screen
Switch' to display the demo switch input. Clicking on this switch will simulate
real switch changes by light gates or contact mats.
|
|
|
Step 3.
|
|
Select view and then click 'Options' to
display the 'Options' window. This window allows you to change the settings of
the false signal processor.
|
Options Window
image to small? LARGER IMAGE
|
|
Step 4.
|
|
Select 'Tests', 'Running' then 'Multiple Gate'
|

Multiple Gate Test Window
image to small? LARGER IMAGE
|
|
Step 5.
|
|
Click the 'On-Screen Switch' to simulate
switch changes. Try clicking twice rapidly so that the time between switch
changes is less than 1000ms, the minimum time set in the Options window.
You should see that the false signals are removed.
|
image to small? LARGER IMAGE
|
|
Step 6.
|
|
After completing a test, press "
Stop" then try setting the 'Minimum Time" on the 'Options Window' to
say 50ms and then press the 'Process False' button on the 'Multiple Gate Test'
window. The false times will now be displayed because they are no longer
less than the minimum switch time specified. In the following example you
will see that the switch changes at 5.619 and 5.797 seconds are within only 178
ms. The extra 'false' switch change would be registered by most systems
and the trial would have to abandoned. with the KMS it is registered as
an extra switch change and thus the last change at 11.237 seconds has a question
mark next to it.
|
image to small? LARGER IMAGE
|
|
Step 7.
|
|
Set the 'Minimum Time' to 1000ms again on
the 'Options' Window and press the 'Process False' button again and you will see
the false signals removed and the correct times are displayed at each of the
gates. You can also try other settings for 'False Signal Processing' such
as 'longest ON' and 'second ON' and observe the results.
|
|
|
|